Low Voltage Soft Starters

LV FCMAplus soft starter

LV FCMAplus soft starter

Our LV FCMAplus soft starters are air-core based series reactors, providing a complete starting solution for any motor application involving pumps, blowers, fans or compressors. We design customized solutions specific to each motor, analysing motor and load torque speed curves, current speed and moment of inertia.

Soft starters are provided with a bypass device (power contactor or air circuit breaker) of customer preferred make. When required by the customer, we offer a complete solution with motor feeder i.e. ACB /power contactor with MPR and metering for switching and protection purpose. All our starters are automated using a PLC with HMI which creates reliability and helps in remote support, allowing for commissioning operation during COVID times.

The standard starting current committed by our soft starters is 3-3.5 times the full load current. We can also reduce the starting current up to 1 to 1.5 times the full load current if required by using a Dynamic Compensator.

Our LV soft starters offer the best competitive value for our customers and offer superior value than the conventional electronic soft starters.

Download Product Brochure Enquire Now
LV FCMAplus soft starter

Our LV FCMAplus soft starters are air-core based series reactors, providing a complete starting solution for any motor application involving pumps, blowers, fans or compressors. We design customized solutions specific to each motor, analyzing motor and load torque speed curves, current speed and moment of inertia.

Soft starters are provided with a bypass device (power contactor or air circuit breaker) of customer preferred make. When required by the customer, we offer a complete solution with motor feeder i.e. ACB /power contactor with MPR and metering for switching and protection purpose. All our starters are automated using a PLC with HMI which creates reliability and helps in remote support, allowing for commissioning operation during COVID times.

The standard starting current committed by our soft starters is 3-3.5 times the full load current. We can also reduce the starting current up to 1 to 1.5 times the full load current if required by using a Dynamic Compensator.

Our LV soft starters offer the best competitive value for our customers and offer superior value than the conventional electronic soft starters.

Download Product Brochure Enquire Now
Technical Specifications
Input Voltage 415V/690V
Motor Power Range Upto 2,000 kW
Application Pump, Compressor, Fan, Blower
Frequency 50Hz/60Hz
Temperature Operation Range 0oC to 55o C
Installation Indoor
Cooling Method Air Cooled
Insulation Class Class F or customized
Standard IEC 60076-6
Construction Air Core, Vacuum Pressure Epoxy Impregnated
Conductor Electrolytic Copper
Starting Current Standard Models: 3-3.5 times starting current
Special Models: 1.5 times full load current with Dynamic Compensator
Reactor variation 5-tap design at 5% voltage difference at each tap
Technical Specifications
Input Voltage 415V/690V
Motor Power Range Upto 2,000 kW
Application Pump, Compressor, Fan, Blower
Frequency 50Hz/60Hz
Temperature Operation Range 0oC to 55o C
Installation Indoor
Cooling Method Air Cooled
Insulation Class Class F or customized
Standard IEC 60076-6
Construction Air Core, Vacuum Pressure Epoxy Impregnated
Conductor Electrolytic Copper
Starting Current Standard Models: 3-3.5 times starting current
Special Models: 1.5 times full load current with Dynamic Compensator
Reactor variation 5-tap design at 5% voltage difference at each tap