Starter Installation in Tyre Factory

Client Overview :

Lecon commissioned an FCMAplus soft starter with a motor feeder and Dynamic compensator (DYCO) panel for a leading tire and rubber manufacturer in Indore in association with a leading American multinational compressor manufacturer The panel was rated at 650KW,3.3KV, with 975 KVAR dynamic compensator.

Technical Challenge:

We needed to design the motor feeder, soft starter and the DYCO panel to be as compact as possible as per customer requirement while meeting customer and Lecon standards. Lecon had to invest significant company resources to come up with an optimal design. A strong requirement by the customer was to limit the starting current to 2 times the full load current to allow for motor starting without damaging internal circuitry.

Lecon Solution:

Unique design of panel included motor feeder, soft starter & Dynamic Compensator with a compact size, which is as per standard. Lecon provided DYCO which is completely current based operation & monitored delay for proper DYCO protection with PLC based control operations.

Result or Outcome:

Lecon successfully designed, manufactured and commissioned FCMAplus soft starter with motor feeder and Dynamic Compensator with the customer-committed starting current. The motor and soft starter continue to successfully operate at site.

Starter Installation in Tyre Factory

Client Overview :

Lecon commissioned an FCMAplus soft starter with a motor feeder and Dynamic compensator (DYCO) panel for a leading tire and rubber manufacturer in Indore in association with a leading American multinational compressor manufacturer The panel was rated at 650KW,3.3KV, with 975 KVAR dynamic compensator.

Technical Challenge:

We needed to design the motor feeder, soft starter and the DYCO panel to be as compact as possible as per customer requirement while meeting customer and Lecon standards. Lecon had to invest significant company resources to come up with an optimal design. A strong requirement by the customer was to limit the starting current to 2 times the full load current to allow for motor starting without damaging internal circuitry.

Lecon Solution:

Unique design of panel included motor feeder, soft starter & Dynamic Compensator with a compact size, which is as per standard. Lecon provided DYCO which is completely current based operation & monitored delay for proper DYCO protection with PLC based control operations.

Result or Outcome:

Lecon successfully designed, manufactured and commissioned FCMAplus soft starter with motor feeder and Dynamic Compensator with the customer-committed starting current. The motor and soft starter continue to successfully operate at site.